automatically downloaded. And if so, you can also decide to allow downloading on mobile internet as well, or
only on LAN. The time of update checking also can be edited. Select from the available updates and then you
can get info about it with „Release notes” button or start the firmware update with „Update now” button.
6.3
Servers
Figure 14. Servers
In the Servers menu item (Figure 14.) you can configure the data needed for the connection to remote
monitoring servers. The module can send signals to 6 different servers simultaneously.
#:
the index of the server
Server name:
You can name the receiver
Server IP:
The
receiver’s IP address
or domain name
Port:
Port number for the IP address
Network:
Use the dropdown menu to set the communication channel for the device to access the remote
monitoring receiver, and also select the backup communication channel. (If the mod
ule doesn’t have an
extension panel, only the LAN can be selected.)
Receiver:
The receiver’s type can be selected from the dropdown
which also fills the port number with the
default value. (If not the default port is used by the receiver, it can be manually updated). The selectable
receiver types are: TEX/MVP (TCP), TELLMon (TCP), TELLMon (UDP), SIA IP (TCP), SIA IP (UDP)
Enable test:
Test report sending towards the given server can be enabled or disabled.
Test interval
: Test report sending frequency in seconds. The module sends test report with the frequency set
here to check the connection with the receiver at the given IP address.