Server selector:
You can select predefined servers from the drop-
down list, or you can also specify „Custom”
servers, in which case Pingable server 1 and 2 fields become editable.
Pingable server 1-2
: Add the IP address of a server which can be accessed only through the router. These
fields are editable only if you select “Custom” option from the dropdown. The field’s backgrou
nd color indicates
whether the IP address is reachable. It turns green if the IP was available, otherwise red.
Ping interval:
The ping attempts' frequency can be set in seconds.
Retry interval for failed ping:
The ping frequency can be increased if no response was received.
Router
’s
warm restart:
Autodetect router IP:
The module automatically detects the router on the same network and fills the
“R
outer
IP address
” field
.
Router IP address:
If the automatic router detection is not enabled, you can manually enter the router's IP
address.
Connection mode:
the module can use two kinds of protocol to restart the router
HTTP
: Restarts the router with an http request
SSH
: Certain routers support commands received via SSH. After selecting SSH connection mode you
can select from the predefined restart commands or you can also add a
„Custom”
one.
Port:
This is the router's authentication port. Also the IP Bridge can log into the router through this port
Username:
Add the username for logging into the router.
Password:
Enter the password for logging into the router.
Number of failed ping attempts for warm restart:
You can set the number of attempts before the module
restarts the router.
Suspend monitoring after restart:
This is the time the module waits before the next ping attempt after the
router was restarted. This value can be modified depending on the time the router restart takes.
Router
’s
cold restart:
Remote module:
You can select which module output you want to be activated when the given event occurs.
By selecting the Local option you can control the outputs of the given device. The Remote 1-6 options allow
you to select from the modules specified in the Remote Modules menu.
Output for router restart:
The router restart event will trigger the status change of the selected output. The
selected output will be displayed in the Outputs menu. It can't be deleted and you can't use it for automatic
output control.
Output activation time:
In this field you can set how long the output status change should take.
Number of warm restart attempts before cold restart:
If the router
’s warm
restart is also set, in this field you
can add how many times to try to warm restart the router before cold restarting it.
Number of failed ping attempts for router restart:
If the warm restart is not enabled, you can add the
maximum number of failed ping attempts before power off and on the router. For cold restart option, you also
need to fill the fields in warm restart section. Cold restart without attempting warm restart is enabled only if the
module
doesn’t support
the router’s
warm restart.
Suspend monitoring after restart:
This is the time the module waits before the next ping attempt after the
router was restarted. This value can be modified depending on the time the router restart takes.