background image

www.teletek-electronics.com

Address: 14A Srebarna Str., 1407 Sofia, Bulgaria

tel.: (+359 2) 9694 700, fax: (+359 2) 962 52 13
e-mail: [email protected]

Distributor:

18020523, 07/2007

Summary of Contents for TP2000

Page 1: ...0 Transmitter and PALM Programmer Installation and Operation Manual This manual is intended for authorized personnel installing TP2000 transmitters on perimeters It does not refer to the end user of the unit ...

Page 2: ...ng of installed products Damages caused by failure to use the product for its normal purpose Damages caused by improper maintenance Damages resulting from any other cause bad maintenance or product misuse In the case of a reasonable number of unsuccessful attempts to repair the product covered by this guarantee the manufacturer s liability shall be limited to the replacement of the product as the ...

Page 3: ...on Field 12 2 2 2 5 Automatic time delay in transmitting an event for mains power supply lost 12 2 2 3 Inputs Tab 13 2 2 3 1 Advanced Properties Screen 15 2 2 3 2 Serial connection with CA60Plus alarm system for transmitting of zone information 17 2 2 4 Test Mode Tab 19 2 2 5 COM Tab 21 2 2 6 Status Bar 22 2 2 7 Value Verification 22 II PALM Programmer 1 Introduction to the PALM PROGRAMMER for TP2...

Page 4: ...d circuit board and a high frequency module in its upper portion The unit is to be found in 3 frequency ranges 150 MHz 300 MHz and 450 MHz Consecutive frequency channels are 12 5 KHz apart Input signals are located in the digital module of the unit and are emitted by the radio transmitter The signal which is sent out is received by a receiver tuned in the same frequency and is decoded by a central...

Page 5: ...s from the coupling 1 2 Installing TP2000 Transmitter The installation of the transmitter starts with its mounting in an appropriate position on the site It is preferable to remove the cover first and take into consideration whether it will be possible to attach the fixing screws after installation has been completed The unit should be mounted where it will have good conditions for transmitting e ...

Page 6: ...rogramming software TP2000 Integrator The button Advanced Properties is moved in the screen Inputs see page 13 The other changes in the TP2000 Integrator software are explained together with the added functions of the TP2000 Transmitter 2 Introduction to TP2000 Integrator TP2000 Integrator is a ancillary program that is part of the transmitter programming suite for the TP2000 TP2001 and TP2000 V 6...

Page 7: ...he transmitter press button To program a transmitter with settings specified in an existing file select the Open Default command from the Bar Menu Open the required file and press the Program XXX button Choose TP2000 ver 6 5 X and this will invoke the Programming Kit for TP2001 v 6 5 Transmitters program which will enable you to store the required settings in the transmitter 2 2 Main Screen of Pro...

Page 8: ...e Bar Menu The Bar Menu of Programming Kit for TP2001 v 6 5 Transmitters accesses the following commands Open Default Button Press this button to open an existing file with parameters for setting up a transmitter Thus you will dispense with the necessity of having to type manually the setting of each field This makes programming much easier for you when you have to set up transmitters on similar p...

Page 9: ... on selecting the Read from Transmitter command 2 2 2 Radio Tab Below the Bar Menu are to be found four tabs that control the basic settings of the unit Radio Inputs Test Mode and COM The first tab you can select from the main screen is Radio the general view of the Radio tab is shown on Figure 3 There are three field groups in this tab Frequency Identification RadioControl as well as a button tha...

Page 10: ...e of the options available in accordance with the central station NONE ODD EVEN Some of the fields will only be available when using a particular protocol Thus the Group and Parity fields will not be active if you have selected the Electronics Line protocol If a field is inactive you will not be allowed to type a value in it When you modify a setting make sure the new value is within the permitted...

Page 11: ...age will be displayed RNA Time field specify an RNA Algorithm for signal transmitting at presence of non restored input The algorithm RNA Repeat Non restored Alarms solves the problem when there is a permanent fault in the wiring at the transmitter input That kind of trouble could be caused of control device fault PGM fault or in case of cutting the cables to the transmitter In case of trouble lik...

Page 12: ...ction solves the problem when there is power supply failure in a residential district and all transmitters try at the same time to transmit a Trouble message in the monitoring station The time delay is specified in seconds and is in arithmetic relationship of the monitored object number the object number is specified by the installer and is introduced in the Address field see Figure 3 on page 7 Th...

Page 13: ...itter inputs from In1 to In8 the Arm Open Close and AC power on inputs The events for which you can require activation i e a signal to be send out are AL the transmitter will send out a signal for an alarm event as soon as a signal is received on the corresponding input RE the transmitter will send out a restore signal on receiving a signal on the corresponding input TR the transmitter will send o...

Page 14: ...visualized throughout the process In the Address and Channel fields you can set up the connection between the physical channel and the logical channels for signal transmission The Address field specifies the address to which the corresponding input is linked The Channel field holds the logical input to be sent Let us assume that four of the transmitter inputs correspond to the first site and the o...

Page 15: ...reens are possible Events to Frequencies when field Logical Reloc has been chosen Figure 11 and Inputs to Frequencies when field Physical Reloc has been chosen Figure 12 In the Input Properties group specify the sensitivity of each input of the transmitter Press and highlight one of the options available 0 1 0 2 0 5 1 2 5 10 or 20 seconds Sensitivity determines the time of stimulation before an ev...

Page 16: ... Restore of the normal charge level of the battery Disarm Disarming the system Arm Arming the system AC Loss Main power supply loss AC Restore Main power supply recovery Power On Power supply on Test The system is in test mode Check one or both boxes next to each event depending on whether you want the signal for this event to be transmitted on Frequency 1 Frequency 2 or on both frequencies at the...

Page 17: ...o sites you can specify their addresses in the Address1 and Address 2 fields and set up a link with the corresponding logical channels for each of them After modifying the values on the fields press button for the changes to be updated or button to discard them and keep the old settings Note In order to be able to choose between the two frequencies you first have to check in the box of the Fx2 Ena...

Page 18: ... single pressing of the RESET button of TP2000 You must also check the field CA62 Serial Connection in the Inputs screen see Figure 15 The system status armed or disarmed is automatically transmitted as Arm Disarm The panel zone alarms are automatically transmitted as input alarms respectively from 1 to 6 Figure 15 Serial connection between Enabling a serial connection between CA60Plus and TP2000 ...

Page 19: ...Addr 2 and for each one a connection can be established with the respective logical channels 2 2 4 Test Mode Tab Third in the main screen comes the Test Mode tab see Figure 16 As desired you can select Test Mode after the programming process of the transmitter has been completed To run the program in this mode the transmitter has to be correctly powered A personal computer will play the part of a ...

Page 20: ...llows Test lights up in light green on sending a test message Battery glows in red when the battery is flat and in green when the charge has been restored AC glows in light green when power has been fed from the mains and in red when power failure has been established Power lights up in light green when power up the transmitter Note If within 30 seconds no input signal has been received the progra...

Page 21: ...ur transmitter is connected see Figure 17 In TP2000 COM Port group select the radio button corresponding to the port to which you have connected your transmitter by means of the PS2 to Canon9 cable you have been provided with Figure 17 The COM Tab In the Port Speed field you can choose the speed of the relevant COM port ...

Page 22: ...itter command is executed 2 2 7 Value Verification After placing the mouse cursor on a field the program will give you a prompt of the range of values that it is allowed to hold For example in the RoundCount on Freq 2 field in the Radio Control group of the Radio tab the number of round repetitions on Frequency 2 only values in the range of 1 to 15 are allowed When you type a value that is not wit...

Page 23: ...PALM PROGRAMMATOR OPERATION MANUAL ...

Page 24: ... PALM The programmer is supplied with an installed programme and batteries After it is turned on the display will show the main menu The main menu can also be turned on from the APPLICATION icon 1 Introduction to the PALM PROGRAMMATOR for TP2000 Regularly observe the battery charge level The installed programme will be deleted if it is not changed in time Should the installed programme be deleted ...

Page 25: ...d programmer select one of the two check boxes RS or IR The standard configuration provides a cable for RS connection 2 There are three buttons in the MAIN screen 3 Press the Program button to save the new parameters 4 To review the parameters from the transmitter press the Get Parameters button 5 Press the Load Save button to load the reviewed or new parameters or to programme any advance loaded ...

Page 26: ...meters programmed in the transmitter For the purpose perform the following in advance Use the provided PS2 cable to connect the programme transmitter to PALM Connect the transmitter to the mains power supply 3 3 Program Button Use this button to load the new parameters in the transmitter For the purpose the transmitter has to be connected to the programmer and to the mains power supply The SerNo a...

Page 27: ...multaneously by two sites where the first address from left to right belongs to the first site The TP2000 v 7 X Transmitter supports three protocols Electronics Line LARS and LARS1 Press and select the name of the required protocol in the Protocol check box Press and select any of the presented options in the Parity check box according to the monitoring station in use NONE ODD EVEN Some of the fie...

Page 28: ... on Freq 1 check box determine the number of repetitions of a packet by Frequency 1 The value introduced must be within the interval of 1 to 15 In the Round Count on Freq 2 check box determine the number of repetitions of a packet by Frequency 2 The value introduced must be within the interval of 1 to 15 In the Round Time check box enter a time interval between the packets within the interval of 0...

Page 29: ...ansmitter input values in this screen Specify the transmitter input parameters from In1 to In8 The events which can be activated i e for which a signal will be received are AL the transmitter sends an alarm status signal when a signal is perceived at the respective input RE the transmitter sends a restore signal when a signal is perceived at the respective input TR the transmitter sends a signal i...

Page 30: ...s are shown on Figure 10 page 14 7 Misc Inputs Screen Figure 24 Misc Inputs Screen of PALM Programmator Set the transmitter arm Open Close and AC input values in the Misc Inputs screen and select the mode for transmitting the battery status The parameters admissible for the arm Open Close input are those permitted for the other inputs with no option for reporting trouble Only AL and RE can be sele...

Page 31: ...roup Press and select any of the offered options 0 1 0 2 0 5 1 2 5 10 or 20 seconds The sensitivity shall determine the action time prior to transmitter event signal transmission RNA Function Selection Select the inputs for transmitting a Trouble message in these check boxes in case of a non restored alarm at the input This can be programmed both for one input as well as for all inputs The transmi...

Page 32: ...ency 1 Frequency 2 or by both frequencies simultaneously Furthermore this screen provides for the option to select whether the events should be transmitted physically or logically via the respective input To this end the respective Physical Relo or Logical Relo check box should be selected the inputs events to be transmitted should be set as well as the frequency and thus the transmitter to be pro...

Page 33: ...encies the Physical Relo check box must be turned on along with the three In1 In2 and In3 check boxes Figure 27 Figure 27 Example 2 If only the Alarm Restore and Trouble logical events need to be transmitted along both frequencies the Logical Relo and the three Alarm Restore and Trouble check boxes have to be turned on Figure 28 Figure 28 ...

Page 34: ...e programme shall correct and alter it to 127 11 TROUBLESHOOTING A possible problem Solution The device does not work when switched on Check the batteries and replace with new ones if necessary Message Error There is no connection with the transmitter Check if the transmitter has been connected to the programmer and has been connected to the mains Message Error Probable connection problem Check th...

Page 35: ... NOTES ...

Page 36: ...www teletek electronics com Address 14A Srebarna Str 1407 Sofia Bulgaria tel 359 2 9694 700 fax 359 2 962 52 13 e mail info teletek electronics bg Distributor 18020523 07 2007 ...

Reviews: