At the inputs 7 and 8 can be programmed additional events for transmitting.
You can choose among the following events:
•
Fuse
- blown out fuse in the СА60Plus control panel.
•
Line error
- Telephone line missing.
•
Communicator error
- error in attempt for transmitting a telephone message.
•
siren
- activated sounder in the configuration of CA60Plus control panel.
•
PGm1
- duplicates the state of output PGM1 of СА60Plus control panel.
The messages for
loss
or
recovery
of main power supply and these for the battery
status are automatically generated and transmitted of the TP2000 Transmitter.
A
Trouble
message will be automatically transmitted to the monitoring station if the serial
connection between TP2000 and CA60Plus has been interrupted.
At using a serial connection with Ca60Plus control panel the physical inputs of the
TP2000 Transmitter have not been scanned.
Time delay in transmitting an event AC (mains power supply lost)
If one transmitter is to be used for two sites, the sites can respectively be set the values
of
addr 1
and
addr 2
and for each one a connection can be established with the
respective logical channels.
2.2.4 Test Mode Tab
Third in the main screen comes the
Test mode
tab, see Figure 16. As desired you
can select
Test mode
after the programming process of the transmitter has been
completed.
To run the program in this mode the transmitter has to be correctly powered. A personal
computer will play the part of a central station that receives the signals.
A table will be displayed on the screen with details on the status of each of the inputs of
the transmitter.
If two sites share one transmitter two columns with indicators will be displayed with the
number of the corresponding site designated above the indicators that refer to it.
The first indicator in the column stands for the
OPen/CLOse input
.
Following it come the eight inputs defined as logical channels
Ch1 - Ch8
.
Below them are to be found the indicators:
•
Test -
stands for a test signal;
•
Battery -
battery status;
•
aC -
power supply;
•
Power -
power on. This indicator will light up only if there is a check in the
PowOnstatus
box of the
radio
tab.
For each of the 8 inputs indicators the light legend is as follows:
•
alarm (red)
stands for activation;
•
restore (light green)
means normal status is restored;
•
Trouble (yellow)
stands for a technical fault.
Summary of Contents for TP2000
Page 23: ...PALM PROGRAMMATOR OPERATION MANUAL ...
Page 35: ... NOTES ...