30
PaLm Programmator
-
Operation Manual
If one transmitter is to be used for two sites, the sites can respectively be set the values of
addr 1
and
addr 2
and for each one a connection can be established with the respective
logical channels.
Assume that four of the transmitter inputs correspond to the first site and the remaining
four - to the second one. Given the inputs to the second site, set “
arm
” (as “Open/Close”)
to one of them. The remaining can be set as
Channel1, Channel2, Channel3
.
NOTE: The Governing Circuit Schemes are shown on Figure 10, page 14.
7. “misc inputs” screen
Figure 24. misc inputs screen of PaLm Programmator
Set the transmitter
arm
(
Open-Close
) and
aC
input values in the
misc inputs
screen
and select the mode for transmitting the battery status.
The parameters, admissible for the
arm
(
Open-Close
) input are those permitted for the
other inputs, with no option for reporting trouble.
Only
aL
and
re
can be selected for
aC
and
BaT
input.
Fuse
,
Line error
,
Comm error
and
siren/PGm1
can be selected for inputs 7 and 8.
Programming these events for the inputs can be accomplished and utilised only after the
transmitter is connected to the
Ca60 Plus
Control Panel and when a serial connection
between the two devices is being used.