14
TP2000 Transmitter
-
Installation and Operation Manual
Colour indication:
•
red -
inactive;
•
green -
active;
•
grey -
status impossible.
To change an event status left-click an indicator.
Placing the cursor of the mouse on the soft button of an input allows visualization of
its connection scheme in the lower left corner of the window. Next to the scheme the
number of the corresponding input will be displayed.
The soft button can be fixed on a particular input by left-clicking the mouse on it. Thus you
will be allowed to set up the status on the other inputs, while the scheme of connection of
the selected input is visualized throughout the process.
In the
address
and
Channel
fields you can set up the connection between the physical
channel and the logical channels for signal transmission.
The
address
field specifies the address to which the corresponding input is linked.
The
Channel
field holds the logical input to be sent.
Let us assume that four of the transmitter inputs correspond to the first site and the other
4 - to the second one. Define one of the inputs on the second site as
arm
, i.e.
Open/
Close
and the other three as
Channel1
,
Channel2
,
Channel3
.
Governing Circuit Scheme
Figure 10. Governing Circuit schemes.
IN
IN
IN
+12V
IN
+12V
IN
EOL
R=2,2K
IN
EOL
R=2,2K
IN
EOL
R=2,2K
IN
IN
+12V
IN
EOL
R=2,2K
IN
IN
+12V
IN
EOL
R=2,2K
Pull up
Pull
Down
Balance
resistor
non-inverted
inverted
aLarm
aLarm
resTOre
resTOre
TrOUBLe
Summary of Contents for TP2000
Page 23: ...PALM PROGRAMMATOR OPERATION MANUAL ...
Page 35: ... NOTES ...