18
Spyder3 SC-34 Color Camera User's Manual
03-032-20116-01
Teledyne DALSA
5
22
Xclk-
18
9
Xclk+
6
21
X3-
19
8
X3+
7
20
SerTC+
20
7
SerTC-
8
19
SerTFG-
21
6
9
18
CC1-
22
5
CC1+
10
17
CC2+
23
4
CC2-
11
16
CC3-
24
3
CC3+
12
15
CC4+
25
2
CC4-
13
13
inner shield
26
26
inner shield
Notes:
*Exterior Overshield is connected to the shells of the connectors on both end s.
**3M p art 14X26-SZLB-XXX-0LC is a com p lete cable assem bly, inclu d ing connectors.
Unu sed p airs shou ld be term inated in 100 ohm s at both end s of the cable.
Inner shield is connected to signal grou nd insid e cam era
Table 10: Camera Control Configuration
Signal
Configuration
CC1
EXSYN C
CC2
PRIN
CC3
Direction
See Ap p end ix B for the com p lete Cam era Link configu ration table, and refer to the Teled yne DALSA Web
site for the official Cam era Link d ocu m ents
(
http :/ / w w w .teled yned alsa.com / m v/ know led ge/ ap p notes.asp x
).
Input Signals, Camera Link
The cam era accep ts control inp u ts throu gh the Cam era Link MDR26F connector.
The camera ships in internal sync, maximum exposure time (exposure mode 7).
EXSYNC (Triggers Line Readout)
Line rate can be set internally u sing the serial interface. The external control sig nal EXSYN C is op tional
and enabled throu gh the serial interface. This cam era u ses the
falling edge of EXSYN C
to trigger p ixel
read ou t. See Setting the Exp osu re Mod e, p age 27, for d etails on how to set line rates, exp osu re tim es, and
cam era m od es.