84
202058 REV AA
6 RU SSPA Chassis Operations Manual
5.1.4 Link Cable
The 9 pin socket J8 connector Link Port is used to link two Redundant SSPAs in order
to pass online/standby status information between them.
Warning! Do not remove this cable while the system is in operation!
The system will not operate properly.
Table 5-2
shows the pin outs of J8.
Figure 5-4
shows an outline drawing of a typical
link cable.
HPA1, P2
HPA2, P3
RF Switch, P1
Description
1 1 B
Common
+28V
3
3
A
Pos 1
2 2 C
Pos
2
Table 5-1: RF Switch Connector Wiring
Figure 5-3: Outline Drawing, Switch Connector Cable
J8 Pin #
Function / Description
6,7
Link Out (connect to “Link In” of Second SSPA)
8,9
Link In (connect to “Link Out” of Second SSPA)
1,2,3,4
Reserved, make no connection
5
Ground (Connect to same pin on Second SSPA)
Table 5-2: Link Port J8 Pin Outs
Figure 5-4: Outline Drawing, Link Port Cable