2.3.2.3 System Address
Sets the network address of the controller if used on a RS-485 network. Choose 1-255.
The factory default address is 0.
Note
: Changes in serial communication settings from the front panel are
effective immediately. Changes to these parameters from serial interface
require that the unit be reset in order to take effect. The units can be re-
set either by cycling power to the unit or by issuing a reset command
from the front panel. See
Section 2.3.5.6
.
2.3.2.4 Interface
User may selected RS232, RS485, IPNet (Ethernet) or SNMP communication.
2.3.2.5 IP Setup
Select between the following menu items:
•
1.IP Info
— This selection allows the user to review all IPNet Settings as
described in
Section 2.3.1.11
through
Section 2.3.1.14
);
•
2.Local IP
— This selection allows the user to set the unit’s Local IP Ad-
dress;
•
3.Subnet Mask
— This selection allows the user to set the Subnet Mask;
•
4.Default Gateway
— This selection allows the user to set the network
Default Gateway Address;
•
5.LocalPort
— This selection allows the user to set the Local Port for the
unit. The default Local Port address is 1007;
•
6.More
— This selection opens the menu items listed in
Section
2.3.2.5.1
.
NewIP:XXX.XXX.XXX.XXX
SubnetMask:XXX.XXX.XXX.XXX
DefGateway:XXX.XXX.XXX.XXX
LocalPort:XXXXX