32
202058 REV AA
6 RU SSPA Chassis Operations Manual
2.3.1.11 IP Info Page 1
This page is available through the Comm. Setup menu, and shows SSPA settings re-
lated to the IP interface.
•
IP Address
– IP address of the SSPA. Consult your network administra-
tor to set this address according to your LAN configuration.
•
MAC
– Medium Access Control address of the SSPA Ethernet controller.
This address is factory preset.
•
Subnet
– IP subnet mask of the SSPA. Consult your network administra-
tor to set this address.
•
IPPort
– IP port value for the SSPA. This address is valid only when IP-
Net protocol is selected. The port value should not be selected outside
the existing services range to avoid access conflict on the M&C PC end.
2.3.1.12 IP Info Page 2
This page shows SSPA settings related to the IP interface.
•
Gateway
– IP Gateway address. This address is used only if access to
the SSPA is provided from an outside LAN. If no such access is required,
the address must be set to 0.0.0.0
•
LockIP
– This address is used to increase the security measure for the
IPNet protocol. The SSPA will answer a request which comes only from a
specified IP address. Set this address value to 255.255.255.255 to disa-
ble this feature. See
Section 2.3.2.5.1
.
2.3.1.13 IP Info Page 3
This page shows SSPA settings related to the IP interface.
•
CommunityGet
– Security string used in SNMP protocol for “Get” re-
quests. Set this value to match the value specified in the NMS or MIB
browser. Maximum string length is 20 alpha-numeric characters. The
string allows read operation for the RM SSPA SNMP agent.
•
CommunitySet
– Security string used in SNMP protocol for “Set” re-
quests. Set this value to match the value specified in the NMS or MIB
browser. For security reasons this string must be different than the Com-
munity Get string. The maximum string length is 20 alpha-numeric char-
acters. The string allows write operation for the RM SSPA SNMP agent.
Note
: Community strings are essentially passwords. The user should use
the same rules for selecting them as for any other passwords: no diction-
ary words, spouse names, etc. An alphanumeric string with mixed upper-
and lower-case letters is generally a good idea.