36
202058 REV AA
6 RU SSPA Chassis Operations Manual
2.3.1.23 N+1 Master Info Page 2
This page displays additional N+1 system operation data, and can be accessed by
pressing the
Up Arrow
(
▲
) key from the N+1 Master Info Page 1. This page is only
accessible from the N+1 Master unit.
•
N+1 Arr.Size
— Displays the N+1 array size. Valid sizes: 2, 4, 8 or 16
units.
•
N+1 Address
— Displays the master unit N+1 priority address;
•
N+1 Alarms
— Displays the number of detected SSPA unit alarms pre-
sent in the system.
•
N+1 State
— Displays the current N+1 fault state. If the Master unit de-
tects no more than one (1) SSPA chassis alarm, the N+1 state will be
displayed as “Normal”; otherwise “FAULT!”.
2.3.1.24 N+1 Master Info Page 3
This page displays information related to N+1 system operation, and can be accessed
by pressing the
Up Arrow
(
▲
) key twice from the N+1 Master Info Page 1. This page
is only accessible from the N+1 Master unit.
•
Cabinet Temp(C)
— Displays the temperature within the system cabinet.
•
Cabinet Fan
— Displays the fault state of the cabinet exhaust impellers.
Possible states are: “Normal”, “FAULT!” or “N/A”.