6 RU SSPA Chassis Operations Manual
202058 REV AA
19
2.1.2.7 Parallel I/O Port (J7) [DB37(F)]
A DB37 female type connector, the Parallel I/O Port contains a series of contact
closures for monitoring HPA faults as well as opto-isolated inputs for controlling some
HPA functions. Inputs react on the closure to ground. The minimal closure time is 50
mS. See
Table 2-3
for a description of the pin outs for this connector.
Table 2-3: Parallel Connector (37 socket D connector)
Pin #
Function / Description
1
Closed on Power Supply Fault Form C relay NC
2
Open on Power Supply Fault Form C relay NO
20
Power Supply Fault Common
21
1. Standalone mode. Closed on Auxiliary Fault;
2. 1:1 Redundancy Mode. Closed on Automatic switchover mode. Form C relay NC
22
1. Standalone Mode. Open on Auxiliary Fault;
2. 1:1 Redundancy Mode. Closed on Manual switchover mode. Form C relay NO
3
Auxiliary Fault\Auto-Manual Common
4
Open on Mute. Form C Relay NC
5
Closed on Mute. Form C Relay NO
23
Mute Status Common
24
Closed on BUC Fault. Form C Relay NC
25
Open on BUC Fault. Form C Relay NO
6
BUC Fault Common
7
Closed on High Temperature Fault. Form C Relay NC
8
Open on High Temperature Fault. Form C Relay NO
26
High Temperature Fault Common
27
1. Standalone mode. Closed on Regulator Low Voltage Fault;
2. 1:1 Redundancy Mode. Closed on HPA Standby. Form C relay NC
28
1. Standalone Mode. Open on Regulator Low Voltage Fault.;
2. 1:1 Redundancy Mode. Closed on HPA Online Mode. Form C relay NO
9
Regulator Low Voltage Fault\Standby-Online Common
10
Closed on DC Current Low Fault. Form C Relay NC
11
Open on DC Current Low Fault. Form C Relay NO
29
DC Current Low Fault Common
30
Closed on Low Forward RF Fault. Form C Relay NC
31
Open on Low Forward RF Form C Relay NO
12
Low Forward RF Fault Common
16
Auto/Manual toggle input. 50mS Closure to isolated ground to activate
17
Mute/Unmute toggle input. 50mS Closure to isolated ground to activate
18
Auxiliary Fault & Auxiliary Mute Input (See
Section 2.1.2.7.1
). 50 ms min.
35
HPA Standby input. 50mS Closure to isolated ground to activate
36
Local/Remote toggle. 50mS Closure to isolated ground to activate
37
Fault clear. 50mS Closure to isolated ground to activate
19
Isolated Signal Ground
15
+5V Isolated Power 20 mA
13, 32
+28V Auxiliary Power 1A
14, 33
Chassis Ground