P/N 02163G Teledyne API Model 300 CO Analyzer Instruction Manual - Page 42
4.11.2 Setting-up Data Channels
To setup a new data channel or modify an existing data channel, press
SETUP-DAS-
EDIT
to get into the DAS edit mode.
Once in the DAS edit mode, definitions of data channels may be created or modified by
using the MENU buttons described in the following table:
Data Channel Edit Menu
Button
Description
PREV
Moves to the previous data channel
NEXT
Moves to the next data channel
INS
Inserts a new data channel in front of the current
one (allowed up to 20 data channels)
DEL
Deletes the current data channel (prompts first)
EDIT
Edits the properties of the current data channel
PRNT
Prints a summary of all of the data channel on the
RS-232 port
The creation or modification of data channel definitions is accomplished by modifying
the
properties
of existing (or default) channel definitions. The table below lists all of the
properties defined for data channels.