15
RELAY SETTINGS FOR T60RX-04#SL, T60RX-08#SL
Latching relay functionality
NOTE! As a default the receiver relays are momentary.
1.
Press the receiver Function button to select Latching relay (LED 7
lights yellow).
2.
Confirm by pressing the Select button (the relay LED above relay 1
lights red).
3.
If yellow LED 7 lights, the current relay is latching. If yellow LED 7
does not light, the current relay isn´t latching. Press the Select
button when the relay LED lights, if you want to assign a latching
functionality to that relay. If not, press the receiver Function button
to move to the next relay. The programming is completed when all
relays have been passed.
4.
When done, press the Select button. Yellow LED 7 flashes to
indicate that at least one of the relays have a latching functionality.
Interlocking relay functionality
Interlocking can be set between relays:
• 1 and 2
• 3 and 4
• 5 and 6 (Robust receiver)
• 7 and 8 (Robust receiver)
1.
Press the receiver Function button to select Interlocking relay (LED
8 lights green).
2.
Confirm by pressing the Select button (the relay LEDs above relay
1 and 2 light red).
3.
If green LED 8 lights, the current relay-pair is interlocked. If green
LED 8 does not light, the current relay-pair isn´t interlocked. Press
the Select button when the relay LEDs lights, if you want to assign
a latching functionality to that relay-pair. If not, press the receiver
Function button to move to the next relay-pair.