14
Fixed, individual (private) ID code
1.
Press the Function button to select Code learning (LED 6 lights
red).
2.
Confirm by pressing the Select button (the relay LEDs light red).
3.
Press the receiver Function button to light up the LED above the
relay that you want to control.
• When you enter, all relays are selected by default and trans-
mitter button 1 controls relay 1, button 2 controls relay 2 etc.
• If you want to make other settings: Press the Function button to
step through the relays one by one. Select a relay by pressing the
Select button. When a relay has been selected, red LED 6 light
red. If it isn´t selected, red LED 6 isn´t lit.
4.
Press the Select button for 0.3-4 seconds.
5.
WITHIN 1 second: Press the Select button again for more than
1 second.
6.
Press the button that is to control the selected relay until LED 6
flashes red 3 times.
Erase ID codes
1. Press the Function button to select Code learning (LED 6 lights red).
2. Confirm by pressing the Select button (the relay LEDs light red).
3. Press the Function button to scroll to the relay(s) that you want to
erase.
4. Press the Select button for more than 6 seconds until the LED(s)
above the relays go out.