![Telair TIG 3000D Use And Maintenance Manual And Instructions For Installation Download Page 18](http://html1.mh-extra.com/html/telair/tig-3000d/tig-3000d_use-and-maintenance-manual-and-instructions-for-installation_1079319018.webp)
TIG 3000 D
Vers. 002
18
GB
6.2 Fuel
Use Diesel oil in compliance with the minimum
requirements as provided for by the following
standards:
EN-590
or
BS-2869-A1/A2
or
ASTM-D-975-
1D/2D
.
At ambient temperatures below 0°C use winter-
type diesel fuel.
6.3 Useful tips
To ensure a long efficiency of the genera-
tor and avoid malfunctioning of any utilities pow-
ered, it is advisable:
- Before starting the set, ensure the utilities are
disconnected (for example via the cutout
switch provided between the generator and
the system as described elsewhere in this
document) until the generator has started and
has reached steady state.
- Before stopping it, disconnect or at least stop
the connected utilities.
- Do not connect power loads exceeding the
maximum power rating; ideally 80% of the
specified rating should not be exceeded so
as to allow for any absorption peaks.
- During the first 50 hours of operation (break-
in) do not to submit the generator to loads
greater than 75% of the rated power
- When the generator is out of use for an ex-
tended period, if it is permanently connected
to a battery, it is recommended that it be run
periodically for half an hour in order to ensure
that the battery remains charged.
7 CONTROL PANEL
The generator is equipped with an original re-
mote control panel from which it is possible to
control its operation (fig.30).
The panel has a access port for connection to an
domotics control unit and a USB port for connec-
tion to a PC.
Controls and signals on the panel (Fig 30):
1 ON/OFF switch: allows control panel activation.
The display 2 and the LED 11 are switched on
2 Display: allows generator operation to be moni-
tored. It shows the operation state and any
messages related to internal diagnostics
3 MENU / BOOST button, dual function key:
pressed normally it allows scrolling the various
menus or confirming the selected options, held
down for at least 3 seconds allows the BOOST
function to be activated or deactivated. This
function must be activated when you are plan-
ning to apply to the generator a single load
with power exceeding 60% of the rated power.
4 Auto button, dual function button: within the
MENUS, it scrolls back through the available
options; with an active panel it allows the
AUTO function to be activated or deactivated.
This function controls the automatic generator
start and stop respectively on reaching the
start threshold and the stop threshold set.
5 Start/Stop button, dual function button: within
the MENUS, it scrolls forward through the
available options; with an active panel it en-
ables the generating set start and stop. Press
it to cancel the AUTO function.
Summary of Contents for TIG 3000D
Page 30: ...TIG 3000 D Vers 002 30 GB 12 TIG 3000D WIRING DIAGRAM ...
Page 31: ...Vers 002 TIG 3000 D 31 GB ...
Page 33: ...Vers 002 TIG 3000 D 33 GB 13 TIG 3000D LIST OF SPARE PARTS ...
Page 34: ...TIG 3000 D Vers 002 34 GB ...
Page 35: ...Vers 002 TIG 3000 D 35 GB ...
Page 36: ...TIG 3000 D Vers 002 36 GB ...
Page 46: ...TIG 3000 D Vers 002 46 GB Notes ...
Page 47: ...Vers 002 TIG 3000 D 47 GB ...
Page 48: ......