Energy 4010 D
Vers. 002
16
GB
Wait a couple of minutes before turning the
generating set off.
In certain situations, the data contained in the
microprocessor inside the panel may be altered.
This may be because the battery is very low, or
because the cables used to connect the battery
to the set have too small cross-sections. Altered
processor data may prevent the generating set
from running; to restore the functionality of
generating set, must reset the control panel.
7.3.2 Automatic Version (optional)
If you wish the start-up batteries to be recharged
automatically in the En 4010D generating sets, it
is possible to install the ASP (optional) automatic
control panel (fig. 25) instead of the manual
control panel.
The elements making it up are:
1 ON/OFF switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicator
5 Start-up failed indicator
6 Generator running indicator (flashing)
7 Maintenance request indicator
8 Fuel reserve indicator
9 Hour or voltmetric changeover switch button
10 Reset
11 Battery charged indicator
12 Automatic function indicator
13 AUTO/MAN switch for the automatic or
manual function
7.4 MANUAL operation
See section 7.1
7.4.1 AUTOMATIC operation
Turn the AUTO/MAN switch (fig. 25 ref. 13) to the
AUTO position and set the start-up switch (fig. 25
ref. 1) to ON position.
The automatic function indicator (fig. 25 ref. 12)
will light up. If the battery which supplies the
generating set has a voltage of more than 11.5
Volts, the battery charged indicator (fig. 25 ref.
11) will light up.
When the voltage at the ends of the 12V DC
terminals of the generating set is lower than 11.5
Volts, the battery charged light indicator (fig. 25
ref. 11) will go off and the generating set will
begin the start-up procedure (similar to that of the
manual operation).
During the operation in automatic mode, the
display
(fig. 25 rif. 2) will show the total running
hours of the generating set. Press the hour or
voltmetric changeover switch button
(fig. 25 ref.
9) to display the voltage at the ends of the 12V
DC terminals, i.e. at the ends of the battery.
When the battery is charged, and anyway after at
least 15 minutes’ running, the battery charged
hours indicator (fig. 25 ref. 11) will light up and
the electronic control panel will turn off the
generating set.
To select automatic or
manual mode is necessary to position the
AUTO / MAN switch before turning on the
panel with the ON / OFF switch..
Remember that the time which is taken by the
generating set in automatic mode to recharge the
battery may vary according to the battery status,
the amount of connected batteries and the ambi-
ent temperature.
Generally, the lower the temperature the less the
time required to charge the battery.
Applying any load higher
than the energy just then available in the
battery will prevent the generating set from
turning on due to insufficient voltage.
Summary of Contents for Energy 4010D
Page 23: ...Vers 002 Energy 4010 D GB 23 12 Energy 4010 D WIRING DIAGRAM...
Page 24: ...Energy 4010 D Vers 002 24 GB 13 energy 4010 d List OF SPARE PARTS...
Page 25: ...Vers 002 Energy 4010 D GB 25...
Page 26: ...Energy 4010 D Vers 002 26 GB...
Page 27: ...Vers 002 Energy 4010 D GB 27...
Page 28: ...Energy 4010 D Vers 002 28 GB...
Page 42: ...Energy 4010 D Vers 002 42 GB Notes...
Page 43: ...Vers 002 Energy 4010 D GB 43 Notes...
Page 44: ......