The oscilloscope controls
The Resources controls
The
Resources
controls contain the menus to select automatic measurements, save and recall
fi
les from internal memory
and external USB drive, reset the oscilloscope to a default setting, and con
fi
gure system parameters such as the oscilloscope
user interface language, time and date, network settings, and much more.
The
Measure
button opens a menu of automated measurements from which to select and display.
The
Save/Recall
button opens the side menu where you can set how to save and recall data. You
can save screen images to external
fi
les, and save and recall waveform data and oscilloscope
settings, t and from internal memory or external
fi
les. (See page 71,
The
Default Setup
button immediately restores the oscilloscope settings (horizontal, vertical, scale,
position, and so on) to the factory default settings. You can use the side menu item to undo the default
setting action. (See page 46,
Setting the oscilloscope to factory default values (Default Setup)
The
Utility
button opens the side menu where you can con
fi
gure system settings such as user
oscilloscope language, date and time, and connectivity (Wi-Fi, LAN, Ethernet), load new oscilloscope
software, and so on. The
Utility
button also provides controls to access and manage
fi
les on a
connected USB drive. (See page 73,
Using the USB File Utility functions
Other front-panel controls
The
Courseware
(graduation cap) button opens a side menu where you can access the Tektronix Courseware lab
exercise functions (See page 93,
Courseware; on-instrument education and training
The
Function
button opens a side menu where you can select optional analysis functions (when available with future
software), the
Scope Intro
oscilloscope theory and feature tour (See page 23,
.), and
Help
Everywhere
on-screen settings and measurements help (See page 21,
Getting on-screen help for settings: Help
The
Autoset
button automatically sets the vertical, horizontal, and trigger controls to acquire and display a usable,
stable waveform.
The
Single
button takes a single waveform acquisition record.
NOTE.
Pushing
Single
stops the oscilloscope continuous signal acquisition mode.
The
Run/Stop
button toggles the oscilloscope between continuously acquiring waveforms (
Run
) and stopping all
waveform acquisitions (
Stop
).
The
File Save
button (located above the side menu buttons) performs an immediate preset save operation. Use the
Save/Recall
menu to set the save action to perform when the save button is pushed
The
Menu On/Off
button (located below the side menu buttons) clears displayed menus from the screen. This button
also turns on and off the display of the measurements readouts and the FFT signal settings.
TBS2000 Series User Manual