Getting Started
9.
Click the
DS1-B
button.
10.
Repeat steps 3 through 7 to verify the DS1-B functionality.
DS3 Functional Veri
fi
cation
This procedure presumes that you are continuing from the DS1
functional veri
fi
cation procedure.
1.
Connect a DS3 75
Ω
coaxial cable between the DS3
RCV
and
XMT
connectors.
2.
Click the
DS3
button.
3.
Click the
Con
fi
guration
tab, and set or con
fi
rm the following
parameters:
Mode =
Term
Framing =
C-Bit
Circuit Timing =
Internal
4.
Click the
Diagnostics
tab, and set or con
fi
rm the following
parameters:
BERT Patterns =
2^23-1
Insert Error =
Logic
and
BPV
5.
Click the
Restart
button. The application Alarms and Events
display shows the message
NO ERRORS
, with a signal level
NetTek YBT100 and YBT100DS3 Backhaul Tester
11