Acquire the Signal
1.
If you select
I2C
, push
De
fi
ne Inputs
and the
appropriate side-bezel menu choices.
B1
I2C
De
fi
ne
Inputs
Thresholds
Include
R/W in
Address
No
B1 Label
I2C
Bus Display Event Table
You can assign the prede
fi
ned
SCLK Input
or
SDA Input
to the channel connected to the
signal.
2.
Push
Include R/W in Address
and then push
the desired side-bezel button.
This control determines how the oscilloscope
shows the I
2
C addresses in bus decode traces,
cursor readouts, Event Table listings, and
trigger settings.
If you select
Yes
, the oscilloscope displays 7-bit addresses as eight bits, where the eighth bit (LSB) is the R/W bit. It displays
10-bit addresses as 11 bits where the third bit is the R/W bit.
If you select
No
, the oscilloscope displays 7-bit addresses as seven bits, and 10-bit addresses as ten bits.
In the physical layer of the I
2
C protocol, 10 bit I
2
C addresses are preceded by the
fi
ve bit code, 11110. The oscilloscope does
not include these
fi
ve bits in address readouts.
110
MSO4000 and DPO4000 Series Oscilloscopes User Manual
Summary of Contents for DPO4032
Page 2: ......
Page 6: ......
Page 12: ...Table of Contents vi MSO4000 and DPO4000 Series Oscilloscopes User Manual...
Page 44: ...Installation 18 MSO4000 and DPO4000 Series Oscilloscopes User Manual...
Page 294: ...Using Application Modules 268 MSO4000 and DPO4000 Series Oscilloscopes User Manual...
Page 344: ...Application Examples 318 MSO4000 and DPO4000 Series Oscilloscopes User Manual...
Page 348: ...Appendix Warranted Specifications 322 MSO4000 and DPO4000 Series Oscilloscopes User Manual...