Serial Mask Testing & Serial Pattern Trigger User Manual
1
Getting Started
This section of the user manual provides a high-level description of the Serial
Mask Testing and Serial Triggering functions. The user Mask functions, Mask
Testing functions and Comm measurements are standard with the CSA7000
Series instruments and both TDS7000 Series Digital Phosphor Oscilloscopes and
TDS6000 Series Digital Sampling Oscilloscopes. All other functions mentioned
in this document are optional for TDS6000 and TDS7000 Series oscilloscopes.
Serial Pattern Trigger is not available on TDS7104 and TDS7054 instruments.
This section also describes how to install Serial Mask Testing and Serial
Triggering functions on TDS6000 and TDS7000 Series instruments.
Product Description
The following text is an overview of the Serial Mask Testing and Serial
Triggering features.
The Serial Mask Testing feature provides optical and electrical mask testing,
communication triggering, and automatic communication signal measurements.
Mask testing consists of two tasks: signal violation detection and pass/fail
testing. Signal violation detection lets you test communications signals for time
or amplitude violations against a predefined mask. Each mask consists of one or
more polygonal regions called segments. The signal waveform data should stay
outside of the segments defined by the mask. Any signal data that occurs inside a
mask segment is called a mask segment violation or “hit.”
You can select from any of the included standard telecommunications masks, or
you can define your own custom masks. Selecting a mask automatically sets the
instrument communications triggers to properly display most communication
signals in the mask.
Pass/Fail testing defines the mask testing parameters, including the number of
waveforms to test, how many mask hits are allowed before failing a test, setting
a mask margin tolerance value, and what action to perform at the completion of a
test.
Communication triggering enables you to trigger on and display waveforms for
industry-standard communications signals. Appendix B lists the supported
standards on which you can trigger.
Automatic communication signal measurements enable you to make automatic
measurements on communications signals. Appendix C lists the available
measurements.
Serial Mask Testing
Summary of Contents for CSA7000 Series
Page 8: ...Preface vi Serial Mask Testing Serial Pattern Trigger User Manual ...
Page 12: ...Getting Started 4 Serial Mask Testing Serial Pattern Trigger User Manual ...
Page 18: ...Operating Basics 10 Serial Mask Testing Serial Pattern Trigger User Manual ...
Page 48: ...Reference 40 Serial Mask Testing Serial Pattern Trigger User Manual ...
Page 62: ...Index 54 Serial Mask Testing Serial Pattern Trigger User Manual ...