6.3.5 Function description
A. Quick Setup
Menu
No.
Step
Function
Function description
Selection list
Default
A.1 Setup Mode
A.1.1
A.1.1
A.1.1
A.1.1
Complete
Complete
Complete
Complete
This follows the steps given in
This follows the steps given in
This follows the steps given in
This follows the steps given in
the Application, Installation,
the Application, Installation,
the Application, Installation,
the Application, Installation,
Conversion and Output setup
Conversion and Output setup
Conversion and Output setup
Conversion and Output setup
modes.
modes.
modes.
modes.
A.1.2
A.1.2
A.1.2
A.1.2
Application
Application
Application
Application
Follow this procedure to
Follow this procedure to
Follow this procedure to
Follow this procedure to
describe the tank contents.
describe the tank contents.
describe the tank contents.
describe the tank contents.
1
Probe Type
Read only
2
Product Type:
Which application
do you have?
The application.
Liquid, Solid
Depends on
the probe
type
3
Air Gap Flag: Do
you have air or gas
above the product?
This tells the device whether or
not there is air or gas above the
product.
Air Gap, No Air Gap
1
Air Gap
4
Number Of
Products: How
many different
products do you
have in the tank?
The number of products in the
tank.
1, 2, >2
2
1
5
Top Product
Liquid:
Liquid:
Liquid:
Liquid: Alcohol, Base,
Hydrocarbon, Liquid Gas,
Mineral Oil, Solvent,
Aqueous Solution, Other
Solid:
Solid:
Solid:
Solid: Cereals, Minerals,
Plastic, Other
6
Application Type:
What do you want
to measure?
Level, Interface,
Level + Interface
3
Level
7
Are the products
mixed or unmixed?
If there are 2+ liquids in the
tank, is there an emulsion in
the tank. This tells the device
to look for the interface when
the two liquids have settled.
Mixed, Unmixed
Unmixed
8
Settings summary
9
Current changes
must be saved or
cancelled before
proceeding
Save, Cancel
4
A.1.3
A.1.3
A.1.3
A.1.3
Installation
Installation
Installation
Installation
Follow this procedure to
Follow this procedure to
Follow this procedure to
Follow this procedure to
describe the process
describe the process
describe the process
describe the process
connection.
connection.
connection.
connection.
1
Tank Height
The distance from the tank
connecting flange face/thread
stop down to the tank bottom.
min-max:
0.165
…
60 m /
0.54
…
196.86 ft
5
2
Installation Type
The type of process connection
on the tank for the device.
Socket, Stillwell (A),
Nozzle (B)
nozzle
3A
Stillwell Height
The height from the tank
connecting flange face/thread
stop to the bottom of the
stillwell.
min-max:
0
…
60 m / 0
…
196.86 ft
1.5 m /
4.92 ft
4A
Stillwell Diameter
The inner diameter of the
stillwell.
min-max:
20
…
1000 mm /
0.79
…
39.37 in
100 mm /
3.94 in
7
0
www.tek-trol.com
Technology Solutions
Instruction Manual
Tek-Flex