1
Attach a lock nut to each end of the rod probe segments.
2
Attach a union nut to the bottom end of each rod probe segment, but not to the bottom seg-
ment. Use two 8 mm open-end wrenches to tighten the union nut against the lock nut.
3
Attach the top segment of the rod probe to the union nut below the process connection. Use
two 8 mm open-end wrenches to tighten the union nut against the lock nut on the rod probe.
4
Attach the middle segment of the rod probe to the union nut on the top segment (if there are
middle segments). Use two 8 mm open-end wrenches to tighten the union nut against the lock
nut. Repeat this step for the other segments.
5
Attach the bottom segment of the rod probe to the union nut on the top segment. Use two
8 mm open-end wrenches to tighten the union nut against the lock nut.
Part 2: How to assemble the segmented single rod probe
Figure 3-32: Part 2: How to assemble the segmented single rod probe
WARNING!
Put a support below the probe to prevent deformation.
CAUTION!
Make sure that the nuts are tight and the rod probe cannot loosen.
39
www.tek-trol.com
Technology Solutions
Instruction Manual
Tek-Flex
4100A