![Teknion Complements Series Installation Manuals Download Page 94](http://html.mh-extra.com/html/teknion/complements-series/complements-series_installation-manuals_1076846094.webp)
NOTE: A video demonstration of
this procedure can be found on
TeknionHub.com titled "Calibrating
Table-2015" or by scanning the
barcode situated at the front of the
base besides the shaft for the
cranking handle.
STEP 11: Estimate and place the load (equipments, devices etc.) on the Worksurface.
Section:
Description:
Page No:
Date:
APPLY LOAD
UNLOCK HEIGHT ADJUSTMENT
COM_115
7 of 10
Sept 2019
ADJUSTABLE WORKSTATION TABLE - COUNTERBALANCE
HEIGHT ADJUSTABLE TABLES (LIVELLO)
L
E
STEP 12a: If adding weight, for every
5 lbs, rotate the CLOCKWISE 8
times.
Do not use excessive force turning
Charge Handle counterclockwise.
STEP 12b: If removing weight, for every 5 lbs rotate
the handle COUNTER CLOCKWISE 8 times.
EXAMPLE: If the weight of approximately 20 lbs is
added to the worksurface, then rotate the handle
CLOCKWISE 32 times. (8 times for each 5 lbs)