STEP 4: Install Magnet on the PIR Module. Attach the PIR underneath the cabinet close to
the light. If this is a wood cabinet, fasten plate as instructed on previous page.
STEP 5: Connect to Power Cord to PIR Module. Connect Daisy Chain to Sensor and Light
and secure wires with the Plastic Clips provided.
STEP 6: Use the Daisy Chain to link under cabinet lights and secure with Plastic Clips
provided.
Section:
Description:
Page No:
Date:
ATTACH PIR TO UNDERSIDE OF SURFACE
CONNECT POWER TO PIR MODULE
LINK ADDITIONAL LIGHTS USING DAISY CHAIN
NOTE
COM_404
4 of 4
Sept 2017
FOR DAISY CHAIN INSTALLATON
LIGHTING
PIR Sensor Switch (Disabled)
PIR Sensor Switch (Enabled)
NOTE: When PIR is Disabled,
sensor is by passed and Light is
always on.
NOTE: When PIR is Enabled,
a blue LED light indicator is ON.
CAUTION!
Handle this step with
care to prenvent fingers
from being pinched.