Manuale d’istruzione per l’installazione, la manutenzione e l’uso
Pentole a gas P70.G7 / P8.G7
05.11.01 - IT
pagina
32
Table 5
– Gas data
Description
P70.G7 / P8.G7
Lower calorific value
H
i
Rated heating power
kW
15,5
Minimum power
kW
7
Gas connection
R”
½”
Consumption
G20
–
2H
m
3
/h
1,64
kWh/m
3
9,45
G30
–
3+
Kg/h
1,22
kWh/kg 12,68
Noz
z
les
di
am
ete
r i
n
1/100 mm
G20
20
mbar
Pilot
40
Maximum
3 X 175
Minimum
ADJUST.
G30
28-
30/37
mbar
Pilot
25
Maximum
3 X 110
Minimum
ADJUST.
Primary air
distance
G20
mm
10
G30
OPEN
Table 6
– Gas inlet pressure
Table 6a
Nominal main pressure
for the different
types of gas
Gas family 2
– Natural
20 mbar
Gas family 3
–LPG
28-30/36 mbar
Table 6b
Operation permissible
if pressure is in the
range:
Gas family 2
– Natural
da 16 a 25 mbar
Gas family 3
–LPG
da 20/25 a 35/45 mbar
Table 6c
Operation non permissible
if pressure is
lower
than:
Gas family 2
– Natural
16 mbar
Gas family 3
–LPG
20/25 mbar
Table 6d
Operation non permissible
if pressure is
higher
than:
Gas family 2
– Natural
25 mbar
Gas family 3
–LPG
35/45mbar