Manuale d’istruzione per l’installazione, la manutenzione e l’uso
Pentole a gas P70.G7 / P8.G7
05.11.01 - IT
pagina
37
2.5.2
.
REPLACEMENT OF INJECTORS FOR PILOT BURNER
–
The injector of the pilot burner can be reached by removing the lower front panel. Remove the side and
lower screws.
–
The pilot burner is in the front of the combustion chamber.
–
Unloose the screw and replace the injector with an appropriate one.
2.5.3. MINIMUM OUTPUT ADJUSTMENT
–
Once the appliance has been switched on, set the cock knob on the minimum position.
Remove the cock knob that will reveal a small hole on the panel of the appliance.
Turn the minimum adjustment screw on the cock with a screwdriver through the hole on the panel.
Warning!
Measure the minimum output pressure directly at the output pressure connection on
the injector tube (see figure “
Measuring gas pressure
”)
Set the output pressure of the gas cock according to the figures stated in table 4 - Minimum output
setting).
After setting, seal the adjustment screw!
Warning!
After each conversion, it is necessary to check tightness and operation!
2.6. MAINTENANCE OF THE APPLIANCE
Warning! :
All maintenance operations shall only be performed by a technically qualified service
centre!
To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year
only. Maintenance includes also to control the components and tear of pipes, feeding pipes etc..
-
It is advisable to replace worn components during maintenance operations to avoid the need for other
maintenance calls and unexpected failures.
It is also advisable to apply for a maintenance contract with the customer.