GB / IE - 1
5410.260.00
Part 1
Installation
FREESTANDING GAS FRYERS
General Instructions
The appliance described in this manual has been built to meet
UNI
EN 203
and
UNI EN 437
standards.
This appliance has been designed exclusively for cooking food, any
other use is considered improper. It should only be used by qualified
personnel in professional kitchens.
The unit must never be left unattended when it is being used! The
appliance should be checked once a year by a qualified technician.
Switch the appliance off in the case of a failure or malfunction.
The appliance should be installed under an extractor hood for removing any cooking fumes.
Care must be taken when using the appliance because the cooking surfaces are very hot.
The appliance must be installed, connected and serviced properly by qualified personnel according to the regulations and
directives in force in the country where it is installed, as well as the instructions in this manual.
Unit characteristics
This instruction manual refers to the installation and use of the
Category II2H3+ gas fryers.
The self-adhesive polyester data plate is behind the control
panel (inside the appliance).
It contains the following information:
Model
FRS35G7
FRS70G7
Serial number:
xxxxxx
Category:
II2H3+
Year of construction:
XXXX
Nominal thermal capacity:
11.5 kW
23 kW
Type of construction:
A1
A1;B21
Test base:
UNI EN 203-1
Connection pressure:
G30
G20
28-30/37 mbar
20 mbar
Consumption:
G30
G20
0.91
1.22
Kg/h
m
3
/h
1.82
2.44
Kg/h
m
3
/h
The supplementary plate is also made of self-adhesive polyester and
is affixed near the data plate; it contains all information regarding the
appliance. The FRS 35G appliance has two burners and a fitting for
gas connection. The FRS 70G appliance has four burners and two
gas connection fittings. The
"G"
gas distribution network fitting
(fig.1) meets ISO 7/1 and ISO 228/1 (DK) standards with a ø ½”
connection, situated at the back of the machine.
The structure of the appliance is made of stainless steel and the
burners are made of steel. All models have adjustable feet.
The main gas pipe is made of galvanised steel. The pipes between
the tap and burner are made of copper.
WARNING!
Install a shut-off cock in the line between the appliance and the gas
distribution network.
Connection to the distribution network
Before you install the appliance make sure that the
gas company has authorised the installation,
compare the data relevant of the appliance (data
plate) with the local supply.
Remove the packaging from the appliance as well as the protective
plastic sheet, and, if necessary, remove traces of glue with a suitable
solvent. To dispose of the packaging, follow local directives (for more
details refer to the chapter “ECOLOGY AND THE ENVIRONMENT”.
Prior to connecting the appliance to the gas network, check the data
plate to see if it has been set and tested for the type of gas and
pressure supplied.
If the gas type or pressure indicated on the data plate is not the
same as that supplied, please refer to the paragraph “CONVERSION
AND ADAPTATION”.
Connect the appliance to the gas distribution network using metal
pipes with a suitable diameter; install a homologated on/off cock
between the appliance and the distribution network.
If flexible pipes are used they must be made of stainless steel
according to the standards in force.
▪
UNI-CIG 8723 safety standard, Act n.46 of the 5th of March 1990
and circular n.68.
▪
Regional and/or local regulations, such as building codes;
▪
Accident prevention regulations in force;
▪
Fire prevention regulations;
▪
Applicable I.E.C. regulations.
We recommend installing the appliance in a well-ventilated
environment, or under an extraction hood to remove the fumes or
vapours produced during the cooking cycle.
The appliance has an equipotential earth terminal “
N
”
(fig.1)at the
back.
The appliance can be installed alone or in line.
Respect a minimum distance of 80mm between the appliance and
any walls made of flammable material, partitions, kitchen furniture or
nearby equipment.
The contact surfaces must be covered with non-combustible heat
insulating material.