GB / IE - 3
5410.260.00
Part 2
Transformation and adaptation
To convert the appliance to another type of gas, e.g. from natural gas
to LPG, the nozzles of the main burner, by-pass and pilot light have
to be changed. All the nozzles are marked with a number that
indicates the diameter in 1/100 and are supplied in a bag.
After each conversion or adaptation, the unit must undergo an
operating test and the supplementary plate must be updated
according to the conversion or adaptation carried out.
Connections to the distribution network, installation, and maintenance of the appliance must only be carried out by qualified
technicians only, in observance of all applicable regulations!
Replacing the nozzles and adjusting the air
BURNER:
Open the doors and find the nozzles (fig.5).
Replace the nozzles “
U
” (fig.5) with suitable ones for the new type of
gas see
nozzles table - T1
in the section
Specifications
.
ADJUSTING THE AIR:
Unscrew the screw holding the primary air adjustment bush. Move
the bush to
the distance “
H
” (fig.7) indicated in the
nozzles table T1
in the section
Specifications
.
Block the bush by tightening its fixing screw.
PILOT LIGHT:
Unscrew and remove the closing nut.
Replace pilot nozzle “
D
” (fig.3) on the basis of the indications in t
he
nozzles table - T1
.
Reassemble the closing nut.