TECNOEKA Srl _____________________________________________________________ use and instruction manual
page. 6 __________________________________________________________________________________________
1.3 Technical specifications
External overall dimension L x D x H
935 x 980 x 1388 mm
Weight
152 Kg
Nominal thermal capacity
17,50 kW
Tray maximal load (GN1/1)
4 kg
Total load (10 trays GN 1/1)
44 kg
ISO 7-1 gas union
1/2 “
Water union
3/4 “
Fume exhaustion vertical tube
Ø 150 mm; height
min. 1000 mm
Appliance category (for Danimarca)
II2H3B/P
Factory adjustment
Methane gas G20 , 20 mbar
Type of construction
B
11
/ B
21
Electrical power
220-230 V ~
Electrical capacity
0,7 kW
Class
I
Power cable type
H07RN-F 3 x 1,5 mm
2
Connecting electric cable
Type Y
Gas connection pressure
Liquid butane/propane gas G30/G31 : 28-30 mbar
Methane gas G20: 20 mbar
Water connection pressure
Max. 200 kPa (2,0 bar)
Gas consumption calculated at low heat value of H
i
at
15° and 1013 mbar
G30 : 1,380 kg / h
G20 : 1,852 m
3
/ h
Parameters to the chimney B
11
(Ø 150 mm, L=1 m)
(G20 20 mbar)
fume load
31.63 g/s
fume temperature
136.8 °C
fume pressure
-2.1 Pa
Parameters to the chimney B
11
(Ø 150 mm, L=1 m)
(G30 28-30 mbar)
fume load
29.60 g/s
fume temperature
141.6 °C
fume pressure
-2.3 Pa
Main injector diameter
G30/G31 : 220
1/100 mm
G20 : 320
1/100 mm
Primary air bush adjustment
G30/G31 : 36 mm
G20 : 24 mm
Table 1
The noise level of the appliance in operation is less than 70 dB (A).
2. General instruction (for installation technician)
The installation technician must make sure that start-up conforms to current national
regulations. The appliance must be installed only by qualified personnel authorised by the
manufacturer. She must observe the safety regulations in force in the country where the
appliance is installed. All extraordinary maintenance jobs (possible adaptation to another type of
gas or replacement of parts) must be performed by qualified personnel having the necessary
professional qualifications. The protected devices and / or sealed by the manufacturer and that
are not intended for maintenance, adjustment, or adaptation to change of gas must not be
handled either by the installer or user. The seals that must be removed to change the gas must
be restored at the end of the adaptation. The manufacturer will not respond for damage to
people, animals and property due to installation errors. Likewise the manufacturer is not
responsible for breakage caused to the appliance by incorrect installation.
2.1 Storage
If the appliance has been stored in a warehouse at a temperature below 0°C (min. allowed is –
5°C), it should be brought to a temperature of at least +10°C before it is turned on.
2.2 Transporting the oven
During transport, the appliance must be left in its original wooden cage to protect it against
damage.
2.3 Unpacking the oven
Remove all the packaging before installation, which is formed of a wooden pallet that holds the
appliance and cardboard casing to protect it. Check that the appliance has not been damaged
during transport and if any damage is discovered immediately inform your retailer and/or the
haulier.