Tecnoware Power Systems
EVO STAR 10-50
33
SYSTEM
Error code Display message
Description
Seriousness
SY1
Inverter w/o load
Inverter without load
Anomaly
SY2
Load on back-up
Load on mains
Anomaly
SY3
Error out voltage
Error in output voltage
User /failure
SY4
High Temperature
Temperature block
Anomaly
SY5
Pretemp. alarm
Critical temperature
Anomaly
SY6
Error direct voltage.
DC Link voltage error
Anomaly
SY7
Mains error
Power supply in alarm
Anomaly
RECTIFIER
Error code Display message
Description
Seriousness
RC1
High Temperature
High Temperature
Anomaly
RC2
Cyclic sense error.
Cyclic sense error.
User
RC3
Rectifier Error
Rectifier alarmed
Failure
RC4
Boost charge
Boost charge activity
User
RC5
Voltage Error
Error in mains voltage
Anomaly
INVERTER
Error code Display message
Description
Seriousness
IV1
Inverter off
Inverter off
User / Anomaly
IV2
Desaturation IGBT
Desaturation IGBT
failure / User
IV3
Voltage Error
Error in inverter voltage
Anomaly /
failure
IV5
Inv. Not synchronised
Error in frequency
synchronism
Anomaly
IV6
Frequency error
Frequency error
Anomaly
IV7
Current > 125%
Output Current > 125%
Anomaly
IV8
Current > 150%
Output Current > 150%
Anomaly
IV9
High current
Output Current outside
parameters
Anomaly
BACK-UP
Error code Display message
Description
Seriousness
RS1
Cyclic sense error.
Cyclic sense error.
User
RS2
Voltage Error
Voltage Error
Anomaly
RS3
Frequency error
Frequency error
Anomaly
BREAKERS
Error code Display message
Description
Seriousness
SZ1
Rectifier Error
Rectifier breaker
User
SZ2
Back-up error
Back-up breaker
User
SZ3
Output error
Output breaker
User
SZ4
By-Pass
Manual By-pass
User
SZ5
Battery error
Battery breaker
User
OP1
User mode
Jumper in the relay board
User
Chart 4