Standard connections - Port 4:
Encoder connection
Note - where a Technolog 120651763
('BH8') cable is attached to this
connector then the terminations are as
above.
The optional open-face sealed, polarised / keyed, M12 'A' coded 'encoder' female connector is provided for the
attachment of external equipment with an 'encoder' interface - the following encoder protocols are supported by Cello 4S
(contact Technolog for further details).
Sensus / Invensys: UI-1203 (fixed field "R..." format, partial support for the variable "V..." format
Neptune: E-Coder 6 digit / E-Coder 8 digit
Kent / Elster "K..." string format
Typical connections:
Note
Refer also to the "Standard connections: Channel mapping & channel shadowing" section of this document.
o
o
o
•
Connector inputs - Encoder 1
Pin
Function
1200651763
'BH8'
2
DATA1 / PULSE1
Brown
8
PWR1 / CLK1
Red
7
GND
Blue
Connector inputs - Encoder 2
Pin
Function
1200651763
'BH8'
4
PWR2 / CLK2
Yellow
6
DATA2 / PULSE2
Pink
5
GND
Grey
Connector inputs - State1
Pin
Function
1200651763
'BH8'
1
STATE1
White
3
GND
Green
This is the default location for the 'Encoder'
connector however it is re-located at Port 6
where either an internal or external pressure
sensor is also required (refer to the
"Standard connections - Port 6: Encoder
connection" section of this document for
further details).
Function
(where x =
Encoder "1" or "2")
Hersey,
Invensys,
Sensus
Schlumberger
Neptune
E-Coder /
ProRead
Kent, Elster
PWRx / CLKx
R
B
Green or
White
DATAx / PULSEx
G
R
Red
GND
B
G