Standard connections - Port 3:
Two signal input (analogue and / or digital) connection
(continued)
Input = Analogue, 4 to 20mA current (loop powered):
+V
GPi2 & / or GPi3
GND (0V)
100
Ω
±
0.1%
precision
resistor
4 to 20mA
Internal pull-up
resistor(s) disabled
in configuration file
Internal debounce
capacitor(s) disabled
in configuration file
Internal pull-down
resistor(s) enabled
in configuration file
330k
Ω