ISOCONTROL: Service & Maintenance Manual - rev. 1.2
Pagina 9.3
9.1.8.2
Machines with 2 encoder boards (refer to paragraph 5.2.2.2 “Pulleys to replace on
Selection machines”.)
1. Using only one lever at a time, perform a single repetition and check that the displacement of
the weight stack in millimeters is correctly shown on the display.
The displayed value should increase when the weight stack is lifted and, conversely,
decrease when the weight stack is lowered.
2. Check that the displayed value returns to 0 when the weight stack is returned to the rest
position.
3. Repeat the operations of steps 1 and 2, varying the load and speed of execution of the exercise.
4. Repeat the operations of steps 1, 2 and 3, using the other lever.
9.1.9. S
AVING THE CONFIGURATION
To exit the menu saving the changes made:
1. Wait for the last menu function to appear (Encoder test). The display should show the message:
0 mm.
2. Simultaneously pressing the “+” and “-” keys for a few seconds.
3. The display will revert to the stand by state.
Summary of Contents for ISOCONTROL
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 2...
Page 2: ......
Page 4: ......
Page 42: ...ISOCONTROL Service Maintenance Manual rev 1 2 Pagina 5 26 Page intentionally left blank...
Page 52: ...ISOCONTROL Service Maintenance Manual rev 1 2 Pagina 6 36 Page intentionally left blank...
Page 58: ...ISOCONTROL Service Maintenance Manual rev 1 2 Pagina 7 6 Page intentionally left blank...
Page 60: ...ISOCONTROL Service Maintenance Manual rev 1 2 Pagina 8 2 Page intentionally left blank...
Page 71: ......