ISOCONTROL: Service & Maintenance Manual - rev. 1.2
Pagina 9.2
To save the machine configuration, see paragraph 9.1.9. “Saving the configuration”; to exit without
saving the changes made, disconnect the power supply form the machine.
9.1.2. R
OM RANGE
This function sets up the value in cm of the default ROM amplitude which is used, prior to
acquisition of the user's actual ROM, to correctly fill in the ROM LED arc on the display. The
display scrolls the ROM RANGE message followed by:
RR:15
These distances are factory configured as detailed in the table below:
MACHINE
Selection Element
MACHINE
Selection Element
ABDOMINA
L CRUNCH
15 15 15
LOW
ROW 20 20 20
ABDUCTOR 16
12
12
LOWER
BACK
27 27 27
ADDUCTOR 16
12
12 MULTI
HIP 16
/
/
ARM
CURL
32 31 31
PECTORAL
20 20 20
ARM
EXTENSION
35 31 31
PULL
DOWN
31 / /
CHEST
INCLINE
27 / /
PULLEY 34 / /
CHEST
PRESS
32 32 32
ROTARY
CALF
40 / /
DELTS 17
/ /
ROTARY
TORSO
13 / /
GLUTE 36
36
36
SHOULDER
PRESS
33 28 28
LAT
MACHINE
50 50 50
TOTAL
ABDOMINAL
16 / /
LEG CURL
41
41
41
UPPER BACK
34
/
/
LEG
EXTENSION
37 37 37
VERTICAL
TRACTION
30 30 30
LEG
PRESS 28 17 17
Use the “+” and “-” keys to bring up the desired value on the display. After reaching the desired
value, wait 5 seconds for the system to automatically advance to the next function.
To save the changes made see paragraph 9.1.9. “Saving the configuration”, to exit without saving
any changes disconnect the power supply form the machine.
9.1.3. S
TART POSITION
This function sets up the distance in cm which the weight stack must move from its rest zone to
enter the exercise zone, which varies depending on the mechanics of the individual machine.
Typically, this displacement is performed using the machine easy-start lever. On the display, the
START POSITION message is followed by:
SP:4
These distances are factory configured as indicated in the table below:
Summary of Contents for ISOCONTROL
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 2...
Page 2: ......
Page 4: ......
Page 42: ...ISOCONTROL Service Maintenance Manual rev 1 2 Pagina 5 26 Page intentionally left blank...