12 Trouble-shooting guide
SFI data:
SFI preview:
maximum 7 days in advance
Timer:
Events:
maximum 30 events, one year
In advance
Remote control system:
RC-5
Subsystem address
8 (SAT 1), 10 (SAT 2)
Modulation frequency
36 kHz
Infra-red wavelength
950 nm
Power supply:
Mains power adapter:
Power requirement:
3.0 W
in stand-by mode (clock off)
3.4 W
in stand-by mode (clock on)
10.5 W in operation, LNB off
18 W
in operation, horizontal polarisa-
tion / 400 mA LNB power
Nominal voltage:
230 V / 50 Hz AC
Input voltage:
180 V.... 250 V / 50 Hz AC
General:
Dimensions (WxDxH):
285 mm x 133 mm x 40 ... 43 mm
Weight:
approx. 490 g
Problem
Possible cause
Solution
Current time not displayed while unit
is in stand-by mode
Time not acquired
Switch to major programme for
approx. 30 secs.
Receiver cannot be switched on, or
cannot be operated
Receiver blocked
Perform Flash Reset: Note!
All personal settings will be lost.
>
Disconnect mains plug.
>
Simultaneously press pro-
gramme up/down key on
receiver and keep pressed
down.
>
While programme up/down
key is pressed, reconnect
mains plug.
>
Keep keys pressed down for
approx. 5 secs. until message
* “FLAS” appears.
50