5.2
Update via GB-A Port
1.
Make sure your networkadapter is configured with an IP-
address in the same range as the
HW-IP address
of the
CaptureModule (10.104.3.96)
2.
Apply “0” to the
rotary switch
3.
Power up the device
4.
Connect a Windows PC with a RJ45 cable directly
to the GB-A-Port of the
CM_100_High
and make sure
there is a link by checking the LEDs blinking. Do not
connect a switch in between.
5.
Start “
Flash ALL_10.104.3.96.bat
” from the same
folder as the firmware files are stored.
6.
Wait until “
Press any key
...“ appears in cmd
-window.
7.
Press any key
8.
Do a power reset
9.
Check the Host-LED if blinking in normal mode.
10.
YES => Please check the version on webserver the
System Information
tab by
browser
NO => redo from point 4.
➔
Finished
Figure 5-1: Update on GB-Port