CM 100 High
User Manual
33
Figure 4-17: Filters Table
Close Edit
: Leave the Edit screen of Filters Table
Clear table
: this button deletes all Filter Entries please press
Apply
after clearance
Add new entry
: adds a new line in the table
Apply
: This Button at the bottom will apply the Filter Entries. For saving them permanently,
please save the configuration and restart the device.
Bus
: Here can be defined the OABR-
Port, to which the filter is applied. “BR 1A” to “BR
6B
”.
Parameter to filter
:
Five different “Parameters to filter” can be set.
IN_VLAN
: inner VLAN ID
OUT_VLAN
: outer VLAN ID
MAC_SRC
: Source MAC Address
MAC_DST
: Destination MAC Address
ETH_TYPE
: Ethertype
Note
: Each “Bus” –
“Parameter to filter” pair is possible
only for once.
Value
: One value in defined format must be typed in this field
IN_VLAN
: Hexadecimal, e.g. 1FB
OUT_VLAN
: Hexadecimal e.g. 1FB
MAC_SRC
: Hexadecimal separated by colon e.g. 11:22:33:aa:bb:cc
MAC_DST
: Hexadecimal separated by colon e.g. 11:22:33:aa:bb:cc
ETH_TYPE
: 2 bytes e.g. 88F7
Action
: only one action is available
DROP
: Each frame that matches the Filter Entry will not be mirrored to the
logging port