CM 100 High
User Manual
35
A maximum of 24 (0-23) rules is possible.
Port
: Please select the port, to which the filter will be applied
Action
:
Here you can define, which filter you want to use:
Drop
: if you want to drop specific frames
Mark
: specific SPY-flag is set in PLP-header
Log without PLP
: not available
Change BusSpecID
: you can change the BusSpecID in PLP
header of specific frames
User Event
: If the filter condition is met then an additional
frame is sent with the field "user event ID" specified in
Parameter
box.
Multiple Log Interfaces
: Here you can define for a specific logged data the logging
port(s) independent from the standard logging port (
Output to
from BASE-T1-Port).
The data is only logged on selected ports.
Parameter
: Parameter is used in
chosen “
Action
:
User Event
”. It
specifies the
UserEventID.
And it is used in “
Action
:
Change BusSpecID
” as value for the new
BusSpecID
.
Multi Log Interfaces
: Only available if
Action: Multi Log Interfaces
is chosen. Any
combination is possible:
GB_A/B/C: Logging on this GB-port
GB_A/B/C: No logging on this GB-port
VLAN Format
:
If the original logged frame contains a VLAN (inner or outer) the corresponding box
must be checked:
OutVlan: The original logged frame has outerVLAN-tag
OutVlan: The original logged frame has no outerVLAN-tag
InVlan: The original logged frame has innerVLAN-tag
InVlan: The original logged frame has no innerVLAN-tag