5-26
EO18-33002A
5. DIAG. TEST OPERATION
5.3 PARAMETER SETTING MODE
1) Check where 2nd print head belongs among rows E~H within the portion
1
.
2) In this example, 2nd print head is printed on the row F. When 2nd print head is printed on the row
E or F, refer to the upper print sample.
When row G or H, refer to the lower print sample.
3) Check where a 2nd print head aligns with the black line (indicated by
2
). Read the scale of the
position (indicated by
3
).
4) Enter the alpha-numerics obtained in steps 1) through 3) into the Head Adjust display. In this case,
enter F1.
■
Adjustment example (CB-426)
X-direction fine adjustment method is explained using 2nd print head.
Feed
X-direction misalignment
E and F :
+ (plus) direction
G and H :
- (minus) direction
These lines indicate Y-
direction alignment.
(When they align and form
an almost straight line, the
adjustment is completed.)
2nd Print
Head
Magenta
2nd Print
Head
3
1
2