5-9
EO18-33002A
5. DIAG. TEST OPERATION
(Revision Date: Dec. 20, 2000)
5.2 SELF TEST MODE
2) Parameters
#
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
Item
FEED [KEY]
FEED [PC]
CUT [PC, KEY]
BACK [KEY]
BACK [PC]
STOP [PC, KEY]
X ADJ.
X DIRECTION
Y DIRECTION
TONE
FONT
CODE
Description
Print start position fine adjustment
Print start position fine adjustment
Cut position fine adjustment
Reverse feed distance fine adjustment
Reverse feed distance fine adjustment
Print stop position fine adjustment
X-coordinate fine adjustment
X-direction fine adjustment
CB-416: Black/Magenta/Cyan/Yellow
CB-426: HEAD1/HEAD2
Y-direction fine adjustment
CB-416: Black/Magenta/Cyan/Yellow
CB-426: HEAD1/HEAD2
Print tone fine adjustment
CB-416: Black/Magenta/Cyan/Yellow
CB-426: HEAD1/HEAD2
Ribbon take-up motor voltage fine adjustment
CB-416: Black/Magenta/Cyan/Yellow
CB-426: HEAD1/HEAD2
Ribbon feed motor voltage fine adjustment
CB-416: Black/Magenta/Cyan/Yellow
CB-426: HEAD1/HEAD2
Character code selection
Font zero selection
Control code selection
Remarks
-30.0 mm ~ +13.0 mm
-30.0 mm ~ +10.0 mm
-20.0 mm ~ +20.0 mm
-9.5 mm ~ +9.5 mm
-9.9 ~ +9.9 mm
-30.0 ~ +300.0 mm
-99.5 mm ~ +99.5 mm
-2.00 mm ~ +2.00 mm
-2.00 mm ~ +2.00 mm
-50 ~ +50 step
-50 ~ +50 setp
-50 ~ +50 setp
PC-850 : PC-850
PC-8: PC-8
0: No slash used.
0: Slash used.
AUTO:
Automatic selection
ESC LF NUL:
ESC LF NUL mode
{ | } : { | } mode
REWIND
SUPPLY
RIBBON
VOLTAGE
NOTES:
1.
Item from (2) through (16) are initialized to “0” after RAM clear.
2.
If the distance is 5.5 m or less, it is rounded down and no data is added to the
memory at power off.
3.
If the count is 31 counts or less, it is rounded down and no data is added to the
memory at power off.
4.
If the driving time is 36 sec. or less, it is rounded down and no data is added to the
memory at power off.
5.
When a sent command results in an error, the same number as the data capacity
of the command is counted by byte.