5-40
EO18-33002A
5. DIAG. TEST OPERATION
(Revision Date: Dec. 20, 2000)
5.3 PARAMETER SETTING MODE
5.3.8
Ribbon Type Selection Mode
Power off
Press the [FEED] key.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G .
V 1 . O A
>
< 2
P A R A M E T E R
S E T
>
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [FEED] key seven times.
P O
I T I O N
S
B L
C K
F 1
A
R I
B O N
B
Press the [PAUSE] key.
Ribbon type selection disply
F1 : Standard ribbon
(CR-30xxx-F1)
P1S : Super premium
ribbon
(CR-30xxx-P1S)
MAGENTA
CYAN
YELLOW
Repeat the above
procedure to other
print heads.
Select the ribbon type with
the [FEED] or [RESTART] key.
Press the [FEED] key
and [RESTART] key
at same time.
Press the [PAUSE] key.
¥CB-416
¥CB-426
H A
D 1
F 1
E
Press the [PAUSE] key.
F1 : Standard ribbon
(CR-30xxx-F1)
P1S : Super premium
ribbon
(CR-30xxx-P1S)
HEAD2
Repeat the above
procedure to 2nd
print head.
Select the ribbon type with
the [FEED] or [RESTART] key.
Press the [FEED] key
and [RESTART] key
at same time.
Press the [PAUSE] key.
NOTES:
1.
Changed settings are stored in the memory by pressing the [PAUSE] key.
2.
Ribbon types can be mixed.
3.
Ribbon type can be selected by the ribbon type selection command from the PC.