5-17
EO18-33002A
5. DIAG. TEST OPERATION
Power off
Press the [FEED] key.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
[FEED] key:
pressing the [FEED] key one
time is a -0.5 mm change, up to
-30.0 mm. (See NOTE 2.)
< 1
D I A G .
V 1 . O A
>
< 2
P A R A M E T E R
S E T
>
[RESTART] key: pressing the [RESTART] key
one time is a +0.5 mm change,
up to +300.0 mm.
(See NOTE 2.)
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [PAUSE] key four times.
P O
I T I O N
S
S T
P
A D J .
+ 0 . 0 m m
O
Press the [FEED] or
[RESTART] key to adjust
the Print stop psition.
(See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Continued on Section 5.3.1. 5
X-Coordinate Fine Adjustment.
Print stop position fine adjustment
Position adjustment mode display
NOTES:
1.
Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
enables a fast forward.
2.
Max. fine adjustment - 30.0 mm, + 300.0 mm = Key fine adjustment value + PC fine
adjustment value.
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3.
A changed feed value is stored in memory by pressing the [PAUSE] key.
5.3 PARAMETER SETTING MODE
5.3.1.4 Print Stop Position Fine Adjustment