Before beginning the installation of the TCS 3000 register, unpack the entire contents of the packaging in a safe loca-
tion where you will not misplace any of the parts. Lay out the parts as they would be installed. This will ensure that
you have all the correct parts for the installation. Verifying all the necessary parts were included in the shipment in
advance will reduce downtime and avoid any wasted preparation work.
Item
Qty
TCS 300871
Metric
TCS 300971
NPT
Phillips Pan
6
TCS300137
TCS300137
Spring Washer
6
TCS300138
TCS300138
Terminal Cover
1
TCS300164
TCS300164
7.5 AMP Fuse
1
TCS300192
TCS300192
Fuse Holder
1
TCS300193
TCS300193
Cable Gland
4
TCS300249
TCS300133
USB Fem/Mini Male Cable
1
TCS300705
TCS300705
Resistor 1K OHM
2
TCS300753
TCS300753
1/4—28 X 3/4 Zinc Bolt
2
TCS68004
TCS68004
1/4—28 X 3/4 Drilled Bolt
2
TCS68004D
TCS68004D
Drive Coupling, 682
1
TCS600420
TCS600420
3/64 X 1 Cotter Pin
1
TCS790091
TCS790091
Installation Procedure:
1.
Remove and put aside the four mounting bolts and any mounting adaptor. Remove the existing mechanical regis-
ter or electronic register, if applicable. Use a box or container to set old equipment and parts in.
2.
Using the shaft specific to your installation, slide the Drive Shaft Coupling on the Pulser Shaft and align the holes.
Once the holes are aligned insert the Cotter Pin and bend the pin ends back around the Drive Coupling.
3.
Slide the Drive Coupling onto the Meter Drive Shaft.
4.
Rotate the TCS 3000 register until the display is facing in the desired direction and check to see that the meter
holes align with the holes at the base of the TCS 3000 register.
5.
Secure the bolts.
682 Drive Coupling
Cotter Pin