![TC Electronic DB6 Manual Download Page 35](http://html2.mh-extra.com/html/tc-electronic/db6/db6_manual_3839394035.webp)
Setting up GPI/O
English Manual (2014-03-05) 31
Select the Preset Bank using the Preset Recall
Scene Bank parameter.
3 Presets DUAL setting
Select one of three Presets using GPI1 and GPI2.
This mode uses simple binary inputs on GPI1
and GPI2 – i.e. 00, 01, 10 and 11.
For a description of the “Idle” state, see “Idle
state” on page 31.
Select the Preset Bank using the Preset Recall
Scene Bank parameter.
4 Presets DUAL setting
Select one of four Presets using GPI1 and GPI2.
This mode uses simple binary inputs on GPI1
and GPI2 – i.e. 00, 01, 10 and 11.
Select the Preset Bank using the Preset Recall
Scene Bank parameter.
15 Presets DUAL setting
Select one of fifteen Presets using GPI1 and
GPI2.
This mode uses 8-state on GPI1 and binary on
GPI2.
For a description of the “Idle” state, see “Idle
state” on page 31.
In this mode, the Scene Presets are always re-
called from two consecutive banks – e.g. Bank 1
and Bank 2.
Select the Preset Bank pairs (1+2, 3+4 etc.) using
the Preset Recall Scene Bank parameter.
16 Presets DUAL setting
Select one of sixteen Presets using GPI1 and
GPI2.
This mode uses 8-state on GPI1 and binary on
GPI2.
In this mode, the Scene Presets are always re-
called from two consecutive banks – e.g. Bank 1
and Bank 2.
Select the Preset Bank pairs (1+2, 3+4 etc.) using
the Preset Recall Scene Bank parameter.
Idle state
“Idle” denotes GPI control being presently not
active – i.e. the unit can still be controlled as nor-
mal, adjusting parameters and recalling presets
via Icon. However, once a non-idle GPI state is
chosen, the selected Scene preset is recalled,
and normal functionality is blocked (which is also
the case when GPI is engaged in general).
GPI 1 – Preset Recall
Scene Bank parameter
If you have set the previously described Preset
Recall Function parameter to any value other
than “Off”, you can select the Bank (or Banks)
that Presets should be chosen from using the
previously described GPI 1 Preset Recall Scene
Bank parameter. See the recall modes for a more
thorough explanation.
Summary of Contents for DB6
Page 2: ......
Page 4: ......
Page 41: ...Updating DB6 firmware English Manual 2014 03 05 37...
Page 73: ...Technical specifications English Manual 2014 03 05 69...
Page 74: ...Technical specifications 70 DB6 Single Multi AES Firmware version 1 30...
Page 75: ...Technical specifications English Manual 2014 03 05 71...
Page 76: ...Technical specifications 72 DB6 Single Multi AES Firmware version 1 30 Item No E60537014...