Options relay function: - Clocks rapidly throughout the
advance warning phase and
slowly when the door is
moving, continued contact
during the hold-open phase
Note
The automatic timer may only be activated within the scope
of DIN EN 12453 provided a safety device is connected.
Note
To be able to set the automatic timer, the photocell must
be activated. For this, set
DIL
-switch
D
to
ON
.
After reaching the OPEN end-of-travel position, the auto-
matic timer starts once the hold-open phase has elapsed.
After generating an impulse, walking or driving past the
photocell, the hold-open phase is automatically extended
by 30 s.
4.6.2
CLOSE end-of-travel signalling
DIL-switch A
➜
OFF / DIL-switch B
➜
ON
(see figure
16.2
)
Operator lighting:
- Permanent light while the door
is moving / persistence time
after CLOSE end-of-travel
position
Options relay function: - CLOSE end-of-travel signalling
4.6.3
Advance warning phase
DIL-switch A
➜
ON / DIL-switch B
➜
OFF
(see figure
16.3
)
Operator lighting:
- Advance warning phase,
flashing rapidly
- Permanent light while the
door is moving
Options relay function: - Clocks slowly while the door
is moving (function of a self-
flashing warning light).
4.6.4 External lighting
DIL-switch A
➜
OFF / DIL-switch B
➜
OFF
(see figure
16.4
)
Operator lighting:
- Permanent light while the door
is moving / persistence time
after CLOSE end-of-travel
position
Options relay function: - Same function as operator
lighting (external lighting)
4.6.5 Door type
DIL-switch C
(see figure
16.5
)
ON
up-and-over door, long "soft" stop ramp
OFF
sectional door, short "soft" stop ramp
4.6.6 Photocell
DIL-switch D
(see figure
16.6
)
ON
activated, after the photocell has been activated,
the door reverses to the OPEN end-of-travel
position
OFF
not activated, automatic timed closing not
possible (DIL-switch A/B)
4.6.7 Stop / static current circuit with self-monitoring
DIL-switch E
(see figure
16.7
)
ON
activated, for wicket door contact with self-
monitoring
OFF
not activated
Note
Safety devices without self-monitoring must be tested
every 6 months.
4.6.8 Door maintenance indication
DIL-switch F
(see figure
16.8
)
ON
activated, if the maintenance cycle has been
exceeded, this is indicated by the operator
lighting flashing several times after each
completed travel cycle.
OFF
not activated, no signal is given if the main-
tenance cycle has been exceeded.
The maintenance interval is arrived at when the operator
has been in service for
more than a year
since the last
learning process, or the operator has completed or
exceeded
2000 closing cycles
.
Note
The maintenance data is reset by repeating the learning
process (see section 4.3).
5
USING THE GARAGE DOOR
Only ever actuate the garage door operator provided
you have full view of the movement range of the door.
Wait until the door has come to a complete standstill
before entering the movement range of the door! Before
driving in or out of the garage, always check that the
door has opened fully.
ATTENTION
Never hang bodily from the pull rope with
knob!
Note
All persons using the door system should be shown how
to operate the garage door operator properly and safely.
Demonstrate and test the mechanical release as well as the
safety return. To do this, halt the closing door by grasping
it with both hands. The door system should gently cut out
and initiate the safety return. The same should happen
during the opening cycle, i.e. the door system gently cuts
out and the door comes to a halt.
5.1
Normal operation
In the normal operation mode the garage door operator
works exclusively by impulse sequential control, whereby
it makes no difference whether an external push-button,
a programmed hand transmitter button or the transparent
push-button is pressed:
1. Impulse: door travels towards an end-of-travel
position
2. Impulse: door stops
3. Impulse: door travels in the opposite direction
4. Impulse: door stops
5. Impulse: door travels towards the end-of-travel
position selected with the 1st impulse
etc.
The operator lighting comes on when the door starts
to move and automatically goes out when the cycle is
completed.
40
02.2006 TR10B005 RE
E N G L I S H
Summary of Contents for TBS 500
Page 13: ...13 02 2006 TR10B005 RE 15 1 3a 1 4a 3 1 ...
Page 18: ...18 02 2006 TR10B005 RE E E 3 1a E E 3a 3 1a ...
Page 19: ...19 02 2006 TR10B005 RE E E E E DF 98 N 80 3 1b 3 1b 3b ...
Page 20: ...20 02 2006 TR10B005 RE 10 4 1 6 3 2 4 5 1 3 2 4 5 2 3 1 1 4 2 3 1 3 4 1 3 1 4 ...
Page 25: ...25 02 2006 TR10B005 RE 4 2 17 4 3 18 4 4 19 2 x 1 x T 1 x T 1 x T ...
Page 26: ...26 02 2006 TR10B005 RE 6 22 21 3 3 7 5 2 20 P 4 5 1 ...
Page 54: ...54 02 2006 TR10B005 RE ...
Page 55: ...55 02 2006 TR10B005 RE ...
Page 56: ...02 2006 TR10B005 RE ...