![TBEA TC500K3US-O Installation Manual Download Page 70](http://html1.mh-extra.com/html/tbea/tc500k3us-o/tc500k3us-o_installation-manual_823554070.webp)
TC500K3US-O Installation Instructions
64
Items
Name
A
Group A fuses (a total of 8 in DC cabinet)
B
Group B fuses (a total of 6 in power cabinet)
C
Group B fuses (a total of 6 in power cabinet)
D
Fuse
E
M10 nuts, spring washers and flat washers combination
(with fuses, tightening torque of 22 N • m)
F
DC positive cables
G
DC negative connection bars
H
M10 bolts, spring washers and flat washers combination
(tightening torque of 22 N • m)
I
DC negative cables
It shall be checked the material of the external terminal connecting
point, if the copper and aluminum materials are interconnected, a special
copper and aluminum connector is needed, don’t directly connected!
(Copper and aluminum connectors can be ordered from TBEA or quality
products may be purchased by the client).
DC side wiring shall ensure that the copper cable specifications of
each copper bar be consistent. Our company will not assume any
responsibility if the user fails to connect as required causing the DC circuit
breaker burned.
DC combiner box according to different rated output current, the inverter
may have 3 wiring schemes as shown in Table.