37
TC500K3US-O shall avoid direct sunlight; otherwise, the higher
temperature will affect the generation.
5.4 Wiring Specifications
Cables used for the system can generally be divided into power cables,
power lines and data lines.
When laying the communication cables, you need to stay away from the
power cables, and the cables at the intersections need to keep a right angle. The
communication cables shall keep the shortest length as far as possible, and
keep a certain distance from the power cables.
The power cables, power lines and data lines shall placed in separate cable
trenches, in order to avoid that the power cables and other cables are aligned
parallelly for a long distance, and reduce the electromagnetic interference
caused by the output voltage transient.
The distance between the power cables, power lines and data lines shall be
greater than 0.2m. In case of the cross-distribution of wires, the crossing angle
shall be of 90 degrees, but the distance can be reduced appropriately.
The corresponding relation of the minimum distance recommended