Energier pro User Manual
38
If your system has two independent AC input sources, you need to install TAI. Please refer to chapter 2.17 for detail introduction.
Connecting two AC input resources to the terminal marked “GEN” and “GRID”.
Connecting the output on terminal marked “OUT”.
Please double check the polarity of the input and output. Wrong connection will damage the
equipment and it is out of warranty.
TAI need to be connected with Energier pro bi-directional inverter with cable supplied. Otherwise,
it will not perform.
Using cables supplied with TAI connecting TAI unit to the “TAI Interface”of Energier pro bi-directional inverter.
TAI port is a 8pin port.
6.9 Install the TAI