You can set Energier pro bi-directional inverter working in power save mode, in which the status consumption power can be
dramatically reduced.
Upon Energier pro bi-directional inverter being set in this mode, Power Save mode LED on front panel will illuminate.
On remote, upon Energier pro bi-directional inverter enter into power saving, the Inverter LED on remote will flash. After resume
normal output, it will illuminate.
7.10 Power Saving mode
If you want to use POWER SAVE mode, you can adjust the standby level by yourself setting the entry level. The range is 0.25%-1%.
Over a period of time, the cells in flooded and OPZS batteries can develop uneven chemical states. This will result in a weak cell which
in turn can reduce the overall capacity of battery. To improve the life and performance of these non sealed batteries, Energier pro
bi-directional inverter includes a manual equalization program that can be used, if recommended by battery manufacturer.
Through the dip switch at central panel, you can initiate the de-sulphation program manually. Once you trigger on the EQ program,
Energierpro bi-directional inverter will perform de-sulphation charging.
It is strongly recommended to read this section carefully before you set the de-sulphation charging and
DO NOT leave battery unattended while performing de-sulphation.
Always check if your battery supplier recommended de-sulphation charging. Only start when it is suitable.
On front panel of Energier pro bi-directional inverter, you can see a switch marked Standby
Level as pictures shows on left.
Switch off all the appliances as you normally do with remote etc.
Using screw driver to slowing turn around the switch from left until you see all power goes off.
It will be the entry level of your Power Save mode.
7.11 Standby level adjustment
7.12 Performing De-sulphation Charging
Summary of Contents for Energier Pro Series
Page 1: ...User Manual Energier Pro series Bi directional inverter TBB Power CO ltd www tbbpower com A3 1...
Page 22: ...Energier pro User Manual 16 3 1 2 RCF remote 3 1 3 Vision Lite 3 1 4 AGS 3 1 5 TAI...
Page 25: ...Energier pro User Manual 19 3 2 4 AGS 3 2 5 TAI...
Page 39: ...Energier pro User Manual 33 CF 2000 VA 4000 VA Model CF 5000 VA 8000 VA Model...